5.5 | Pre-designed Projects & Data

Level COMMAND Manual (EN) 5 | Operational Workflows

Pre-designed Projects allow Level COMMAND to grade using surfaces that have been created outside the application. These projects are typically prepared by a dealer, surveyor or designer before being transferred to the machine. Compared with Plane Projects, imp...

lc
load
LC-Referenced
LoadProject.xaml.cs
LC-Referenced
ImportFile.xaml.cs
LC-Referenced
ImportChooseProjection.xaml.cs
LC-Referenced
ProjectDetails.xaml.cs

5.7 | Markers & Benchmarks

Level COMMAND Manual (EN) 5 | Operational Workflows

Level COMMAND allows important locations within a project to be recorded using Markers and Benchmarks. Although both are created using the same tool, they serve different purposes during surveying, grading and future site visits. Markers provide useful refere...

lc
markers
LC-Referenced
MarkerWindow.xaml.cs
LC-Referenced
POICreationTool.xaml.cs

7.1 | Appearance

Level COMMAND Manual (EN) 7 | Settings & Preferences

The Appearance page allows you to customise how Level COMMAND is displayed. These settings only affect the user interface and map presentation—they do not change how the guidance or automatic control system operates. Brightness Adjusts the display brightness...

lc
appearance
LC-Referenced
AppearanceWindow.xaml.cs

7.2 | Units

Level COMMAND Manual (EN) 7 | Settings & Preferences

The Units page allows you to select the measurement units used throughout Level COMMAND. The available unit categories are: Length / Height – Millimetres, Centimetres, Metres, Inches, or Feet. Volume – Cubic Metres, Cubic Yards, or Cubic Feet. Area – Hectare...

lc
units
LC-Referenced
LanguageUnitsWindow.xaml.cs

7.3 | Language & Accessibility

Level COMMAND Manual (EN) 7 | Settings & Preferences

The Language & Accessibility page allows you to customise the interface language and on-screen keyboard behaviour to suit your device and operating preferences. Language Selects the display language used throughout Level COMMAND. For the best experience, res...

lc
language
LC-Referenced
AccessibilityWindow.xaml.cs

7.5 | Licensing

Level COMMAND Manual (EN) 7 | Settings & Preferences

The Licensing page is used to activate Level COMMAND and register the software for normal operation. To open the Licensing page, press More → License. A valid licence is required for normal operation. If Level COMMAND has not been activated, a Demo Mode banne...

lc
licensing
LC-Referenced
LicensingLevelCommand.xaml.cs

7.6 | Support & Error Reporting

Level COMMAND Manual (EN) 7 | Settings & Preferences

The Support & Error Reporting tools allow operators and dealers to receive remote assistance and provide feedback directly to T3RRA. To access the Error Reporter, press More → Report. An internet connection is required for Remote Support and sending reports. ...

lc
support
LC-Referenced
GetSupport.xaml.cs
LC-Referenced
ExceptionWindow.xaml.cs

7 | Settings & Preferences

Level COMMAND Manual (EN)

This chapter describes the application settings used to customise the Level COMMAND user experience. It covers display preferences, measurement units, language, software updates, licensing, support tools and advanced application settings.

lc
settings

7.4 | Updates & Release Management

Level COMMAND Manual (EN) 7 | Settings & Preferences

The Update/Changelog page allows you to keep Level COMMAND up to date and review changes introduced in each software release. Keeping the software current provides access to new features, performance improvements and bug fixes. However, if the system is opera...

lc
update
LC-Referenced
UpdateChangeLogWindow.xaml.cs

3.1 | Connecting to the COMMAND ECU

Level COMMAND Manual (EN) 3 | Dealer Installation & Commissioning

To access COMMAND ECU settings from the Apply View, press "More" at the right side of the screen, then "COMMAND Settings". The COMMAND Settings Overview page shows each page related to operation of the ECU. The Machine page is used to setup the connection be...

lc
machine
LC-Referenced
0.CommandSettingsSplash.xaml.cs
LC-Referenced
1.MachineSettings.xaml.cs

3.4 | Configuring GNSS

Level COMMAND Manual (EN) 3 | Dealer Installation & Commissioning

The Inputs/Offsets page is used for selection of input sensors, such as GNSS receivers for height control or Inertial Measurement Units (IMU) for terrain compensation and Tilt / X-slope control. GNSS Input Configuration Inputs All COMMAND machine profiles ...

lc
inputsOffsets
LC-Referenced
GPSErrorThresholds.xaml.cs
LC-Referenced
2.InputsOffsetsSettings.xaml.cs

3.5 | Configuring Valve Outputs

Level COMMAND Manual (EN) 3 | Dealer Installation & Commissioning

The Valve Configs page is used to set up the control output interface for each control function. Appropriate signals of that interface type are then generated when automatic or manually controlling the implement. External joystick inputs are also configured o...

lc
valveConfigs
LC-Referenced
4.ValveCalibration.xaml.cs

3.6 | Valve Threshold Calibration

Level COMMAND Manual (EN) 3 | Dealer Installation & Commissioning

Valve Threshold Calibration establishes the minimum and maximum hydraulic outputs used by Automatic Control. Correct calibration ensures the implement can move smoothly for small corrections while still achieving full operating speed when required. Access the ...

lc
ValveCals
LC-Referenced
6.TuningSettings.xaml.cs

3.7 | Cylinder Ratio Calibration

Level COMMAND Manual (EN) 3 | Dealer Installation & Commissioning

Overview Cylinder Ratio Calibration compensates for differences in implement movement speeds between opposing control directions. Hydraulic systems rarely move at identical speeds in both directions. Differences in cylinder geometry, implement weight, hydraul...

lc
Cylinder
LC-Referenced
5.CylinderCalibration.xaml.cs

3.8 | Tuning Automatic Implement Control

Level COMMAND Manual (EN) 3 | Dealer Installation & Commissioning

The purpose of tuning is to achieve stable, accurate Automatic Control that follows the design surface smoothly without excessive lag or oscillation. The Tuning page provides the controls and feedback required to optimise control performance. To find the tunin...

lc
tuning
LC-Referenced
4.ValveCalibration.xaml.cs

3.2 | Checking for Software & Firmware Updates

Level COMMAND Manual (EN) 3 | Dealer Installation & Commissioning

Before proceeding with machine configuration and calibration, ensure both the Level COMMAND application and the COMMAND ECU are updated to the latest available versions. Recommended Procedure Connect to the COMMAND ECU successfully as performed in section 3.1...

lc
adminSettings
LC-Referenced
OnlineUpdateWindow.xaml.cs
LC-Referenced
8.AdminSettings.xaml.cs