6.6 | Tractor CAN Connection (Optional)

Overview

COMMAND can be connected to a 250 or 500kbps Tractor CANBUS if present, allowing the ECU to read tractor data directly from tractor systems including parameters such as engine load, hydraulic oil temperature, wheel speed and instantaneous fuel usage. This data can then be displayed in the widgets in Level COMMAND in real-time, and is also used in the background for certain control features.

Required Parts

A port replicator is included on the T3H-M001 adapter so that other devices may be connected to the diagnostic connector when necessary without removal of COMMAND harnessing.

Type I J1939 Diagnostic Connection (Black)image.png

If the tractor has a Type I diagnostic connection, T3H-X004 should be added to maintain the Type I connection for the tractor.

  • T3H-M001 - COMMAND J1939 Diagnostic Adapter (Green)
  • T3H-X004 -  MTG Adapter – J1939 Type 1 Black to Type 2 Green

Type II J1939 Diagnostic Connection (Greenimage.png

  • T3H-M001 - COMMAND J1939 Diagnostic Adapter (Green)

image.png

(Image Source & Credit: https://www.diesellaptops.com/blogs/news/the-new-green-9-pin-j1939-connectors-explained)


Connection Process

image.png

IMPORTANT: T3H-M001 is specifically designed for diagnostics connectors with ISOBUS or Implement CANBUS, and tractor CANBUS access. Connecting to a diagnostic plug that is linked to other CANBUS' may cause tractor system errors.

  1. Connect the T3H-M001 adapter to the appropriate diagnostic plug in the cab of the tractor
  2. Connect the T3H-M001 adapter to the T3H-C006 Cab Breakout Adapter.
  3. If appropriate tractor data is present on the tractor bus, COMMAND will begin reading the data and providing it to Level COMMAND software.
  4. Check whether any new widgets have appeared with new data in the Widgets menu of Level COMMAND.

image.png