5.6 | Surveying & Field Data Collection

Level COMMAND Manual (EN) 5 | Operational Workflows

The Survey tool records GNSS-referenced terrain and feature data for design creation, project verification, and archival purposes. Collect a survey before grading to capture existing ground, or after grading to verify completed work. Survey data can be exporte...

5.7 | Markers & Benchmarks

Level COMMAND Manual (EN) 5 | Operational Workflows

Level COMMAND allows important locations within a project to be recorded using Markers and Benchmarks. Although both are created using the same tool, they serve different purposes during surveying, grading and future site visits. Markers provide useful refere...

lc
markers
LC-Referenced
MarkerWindow.xaml.cs
LC-Referenced
POICreationTool.xaml.cs

5.8 | Choosing a Zeroing Method

Level COMMAND Manual (EN) 5 | Operational Workflows

Selecting the correct zeroing method depends on how the current project was created and whether a suitable Benchmark is available. The table below summarises the recommended workflow for the most common situations. If your project is... Recommended zeroing ...

6.2 | Automatic Blade Control

Level COMMAND Manual (EN) 6 | Automatic Control & Surface Behaviour

Automatic Blade Control is the process Level COMMAND uses to guide the implement towards the required target position while grading. Once Automatic Control is engaged, Level COMMAND continually monitors the implement position, compares it with the required tar...

6.4 | Blade Shift & Target Adjustment

Level COMMAND Manual (EN) 6 | Automatic Control & Surface Behaviour

Blade Shift allows the operator to temporarily adjust the Target Position during grading. This provides a quick method of making small grading adjustments to suit changing site conditions without changing the project itself. Blade Shift changes the current Tar...

LC-Referenced
BladeShiftSettings.xaml.cs
LC-Referenced
NudgeSlopeTool.xaml.cs

6.5 | Reliable Positioning

Level COMMAND Manual (EN) 6 | Automatic Control & Surface Behaviour

The accuracy of Automatic Control depends directly on the quality of the positioning information received from the GNSS receivers. Every control decision made by Level COMMAND begins with a measured implement position. If that position is inaccurate, the calcu...

6.6 | Automatic Control Tuning

Level COMMAND Manual (EN) 6 | Automatic Control & Surface Behaviour

The quality of Automatic Control is determined by several systems working together. Poor grading performance is often caused by multiple small issues rather than a single fault. Rather than immediately adjusting tuning or calibration values, verify that each s...

6.7 | Look Ahead

Level COMMAND Manual (EN) 6 | Automatic Control & Surface Behaviour

Hydraulic systems require a short amount of time to respond after a control command is issued. Oil must flow, hydraulic cylinders must move and the implement must physically react before the blade reaches its new position. To compensate for this delay, Level ...

6.8 | Tandem Blade Behaviour

Level COMMAND Manual (EN) 6 | Automatic Control & Surface Behaviour

The Tandem Scraper profile allows Level COMMAND to control two trailing scrapers independently during the same grading operation. Although each scraper is controlled separately, the overall operating workflow remains almost identical to a single scraper. Most ...

3.2 | Checking for Software & Firmware Updates

Level COMMAND Manual (EN) 3 | Dealer Installation & Commissioning

Before proceeding with machine configuration and calibration, ensure both the Level COMMAND application and the COMMAND ECU are updated to the latest available versions. Recommended Procedure Connect to the COMMAND ECU successfully as performed in section 3.1...

lc
adminSettings
LC-Referenced
OnlineUpdateWindow.xaml.cs
LC-Referenced
8.AdminSettings.xaml.cs

4.2 | Understanding COMMAND Status

Level COMMAND Manual (EN) 4 | Operator Quick Start

The COMMAND Status area is shown at the bottom-right of the Apply View and provides a quick indication of the current operating state of the COMMAND ECU. Operators should check COMMAND Status before attempting to engage Automatic Control. The status message i...

6.1 | Understanding Surface Layers

Level COMMAND Manual (EN) 6 | Automatic Control & Surface Behaviour

Every grading operation performed by Level COMMAND is based on one or more surface layers. Although only a single machine is moving across the field, Level COMMAND continuously compares several different representations of the terrain to determine where the im...

Appendix A | COMMAND Settings Reference

Level COMMAND Manual (EN)

Introduction The COMMAND Settings pages provide access to the configuration and diagnostic functions of the COMMAND Electronic Control Unit (ECU). During a new installation, these pages are used to commission the machine as described in Chapter 3 | Dealer Comm...

Intended Use

T3RRA Operator's Manual 1. General

T3RRA In-cab Software is intended for use on supported construction, landforming, and earthmoving machinery equipped with compatible hardware, GNSS receivers, hydraulic interfaces, and machine sensors. The system is designed to assist operators with terrain gu...

7.5 | Versatile — Analog Scraper Control

COMMAND Manual (EN) 7 | Tractor / External Valve Connection...

Applicable to: Supported Versatile L4WD and DeltaTrack tractors fitted with the 6-pin C920 laser/scraper control interface connected to the tractor Gateway Control Module (GCM). NOTE: MFWD models may use a different interface arrangement. The 400 HP R3T3 MFWD ...

7.6 | External Proportional Solenoid Valves — Direct PWM Coil Drive

COMMAND Manual (EN) 7 | Tractor / External Valve Connection...

Applicable to: External proportional valves with solenoid coils driven directly by COMMAND’s PWM outputs. For valves fitted with Danfoss PVE electronic actuators, refer to the Danfoss PVE installation section. IMPORTANT: Confirm that the external valve’s elect...

7.7 | Fendt ONE — 900 Gen 6/7 & 1000 Gen 2/3

COMMAND Manual (EN) 7 | Tractor / External Valve Connection...

Applicable to: Supported Fendt 900 Gen 6/7 and Fendt 1000 Gen 2/3 tractors using the COMMAND Fendt ONE valve interface. Connection Method COMMAND connects to the tractor’s rear SCV system using the T3H-V005 ISO Valve Adapter. The adapter is installed inline be...

7.9 | Fendt 900 SCR/S4

COMMAND Manual (EN) 7 | Tractor / External Valve Connection...

Applicable to: Supported Fendt 900 SCR/S4 tractors using the COMMAND Fendt SCR/S4/MT valve interface. Connection Method COMMAND connects to the tractor’s rear SCV system using the T3H-V005 ISO Valve Adapter and the S/111 — Fendt 900 S4/SCR Adapter Harness. The...