Connecting COMMAND to the ISOBUS
ECU Mounted In-cab


With the COMMAND ECU mounted in-cab, the 4-way ISOBUS connection on the T3H-C006 cab breakout harness can be connected to the 4-way ISOBUS plug if a suitable connection is present within the cab.
Harnessing can be used to connect the T3H-C006 cab breakout harness to a 9-way in-cab ISOBUS receptacle.
ECU Mounted at Rear of Tractor
With the COMMAND ECU mounted at the rear panel or near the ISOBUS breakaway plug, the 4-way ISOBUS "T" connection on the T3H-C005 external breakout harness should be connected to the 4-way ISOBUS connection at the back of the ISOBUS breakaway connector.
Unplug the existing 4-way plug that's inserted into the breakaway plug and connect this to the T3H-C005 ISOBUS "T" connection, then connect the 4-way plug on T3H-C005 to the implement breakaway plug's 4-pin receptacle.