# Baud rate is set correctly but messages from iGrade are still garbled. **Symptoms**: Baud rates are set correctly on both T3RRA software and in iGrade. The T3RRA software is not receiving GPS and the GPS diagnostics window is showing an unintelligible data stream. ![](https://docs.t3rra.com/uploads/images/gallery/2025-03/scaled-1680-/fc5w5a2oknysdhonlqxwgqe2-gyydhbg7w-png.png) **Causes**: The serial connection is not properly grounded. Pin 5 is disconnected or connected to the wrong pin at the other end of the cable. **Solutions**: Carefully check the remote control cable and the iGrade harness. Ensure that the ground wire is properly grounded. In at least one case we have had a user report that an additional grounding wire was required as shown below. ![](https://docs.t3rra.com/uploads/images/gallery/2025-03/scaled-1680-/rwy05ria6tepkpy-hknm-3ykumeeezy8tw-png.png)