9.1 | Starting Implementation

T3RRA Software implementation startup instructions for UCC1

  1. Drive to a zero cut/fill area and place the scraper cutting edge on the ground. Drop a marker for future reference. When zeroing on drains, ensure that the position indicator is on the drain surface.

    Cut/fill indicator showing 0.00m Marker button with a location pin symbol

  2. Select Set Zero to zero the T3RRA Cutta, choose Zero against the surface, then select OK.

    Set Zero button with arrows pointing toward a zero symbol Zeroing dialog with Zero against the surface selected and Ok and Cancel buttons

  3. Select Start in your T3RRA software to begin implementation, then press Set Offset – Zero Error on the iGrade*.

    Start button with a green triangle Remote Control Main screen with Control Error 0.00 and Set Offset - Zero Error circled

  4. Place the applicable SCV’s in the Detent position, not float, to set iGrade™ to automatic control.

    Hand operating an SCV lever on the tractor console

T3RRA Software implementation startup instructions for UCC2

  1. Drive to a zero cut/fill area and place the scraper cutting edge on the ground. Drop a marker for future reference. When zeroing on drains, ensure that the position indicator is on the drain surface.

    Cut/fill indicator showing 0.00m Marker button with a location pin symbol

  2. Select Set Zero to zero the T3RRA, choose Zero against the surface, then select OK.

    Set Zero button with arrows pointing toward a zero symbol Zeroing dialog with Zero against the surface selected and Ok and Cancel buttons

  3. Select Start to start sending commands to iGrade.

    Start button with a green triangle

  4. Verify that Elevation Error remains 0.00. If not, press the Set Zero Error Button on the iGrade*.

    Elevation screen showing Elevation Error 0.00 m and the Set Zero Error button marked A

Notes


Created 2025-03-04 22:17:13 UTC by Hugo
Updated 2026-10-12 05:22:46 UTC by Sathya